Reasons for the lack of tight valves and treatment methods

When the valve is in use, there are often some troublesome problems. For example, if the valve is not tight and the door is not tight, what should I do?

Under normal circumstances, if the door is not tight, first check to see if the valve is closed. If it is closed, there is still a leak and it cannot be sealed. Then, when checking the sealing surface, some valve sealing pairs are available. If it is disassembled, it will be taken out for grinding and tested again. Of course, if it is still not tight, it must be returned to the factory for repair or replacement of the valve, so as not to affect the normal use of the valve and the occurrence of working conditions.

If the valve is not tight, you should first find out where the problem is, and then solve the problem according to the corresponding method. There are several reasons why the general valve is not tight:

(1) Impurities are stuck on the sealing surface, and debris is deposited at the bottom of the valve or between the valve flap and the valve seat;

(2) The stem thread is rusted and the valve cannot be rotated;

(3) The sealing surface of the valve is damaged, causing leakage of the medium;

(4) The valve stem and the valve disc are not well connected, so that the valve disc and the valve seat are not in close contact with each other.

The valve is not tightly handled:

First, there are impurities stuck to the valve sealing surface

Sometimes the valve is suddenly closed, and there may be impurities stuck between the sealing surfaces of the valve. At this time, the force is forcibly closed. The valve should be slightly opened, and then try to close it. Try it repeatedly, generally it can be eliminated. Otherwise, it should be For inspection, the quality of the media should be kept clean.

Second, the stem thread rust

For valves that are normally open, when the valve is accidentally closed, the valve stem thread has rusted, and the valve may not be tight. In this case, the valve can be repeatedly switched and closed, and the bottom of the valve body is struck with a small hammer, so that the valve can be closed, and the valve does not need to be ground and repaired.

Third, the valve sealing surface is destroyed

For the case where the switch is still closed, the sealing surface is damaged and should be repaired; or the corrosion, the grain scratches in the medium, etc., damage the sealing surface and should be repaired.

Fourth, the valve stem and the valve flap are not connected well.

Lubricate the stem and stem nut frequently to ensure flexible valve switching. Have a formal maintenance plan.